PATIENT MONITOR CETUS x12

  • Model: CETUS x12
  • Manufacturer: Axcent Medical
  • Origin: Germany

PATIENT MONITOR CETUS x12

Model: CETUS x12

Manufacturer: Axcent Medical

Origin: Germany

Specifications:

Features:

  • Patient: Adult, pediatric, neonatal
  • 1” color TFT LCD screen
  • 8 waveform display, up to 12-lead ECG analysis
  • ST & arrhythmia analysis
  • Wired/Wireless CMS, support HL7 protocol to HIS
  • MEWS (Modified Early Warning Score)
  • Graphical & tabular trend review (120 hours)
  • Rechargeable Lithium-Ion Battery (2600 mAh)

Display

  • 1” TFT
  • Resolution: 800 x 600
  • Number of traces: 8 waveforms

ECG

  • Lead type: 3-lead, 5-lead, 12-lead
  • ECG waveform: 2 channels, 7 channels, 12 channels
  • Display sensitivity: 2.5 mm/mV (×0.25), 5 mm/mV (×0.5), 10 mm/mV (×1.0), 20 mm/mV (×2.0)
  • Wave sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
  • Differential input impedance >5MΩ
  • Electrode polarization voltage range: ±400 mV
  • Baseline recovery time <3s after defibrillation (in monitor and surgery mode)
  • Calibration signal: 1mV (peak – peak), accuracy ±3%

RESP

  • Measurement method: Thoracic electrical bioimpedance
  • Rate: 0 – 150 bpm
  • Measuring lead: Lead I, II
  • Wave gain: ×0.25, ×0.5, ×1, ×2
  • Respiratory impedance range: 0.5-5Ω
  • Baseline impedance: 500-4000Ω
  • Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s

Pulse Rate

  • Range: 30~254 bpm
  • Resolution: 1bpm
  • Accuracy: ±2bpm (non-motion), ±5bpm (motion)
  • Refreshing rate: 1s

TEMP

  • Accuracy: ±0.1 °C or ±0.2 °F (without probe)
  • Measurement range: 5~50 °C (41~122 °F)
  • Channel: Two channels
  • Resolution: 0.1 °C

NIBP

  • Measurement method: Automatic oscillometric method
  • Operating mode: Manual, automatic, continuous
  • Measurement unit: mmHg/kPa selectable
  • Typical measurement time: 20~40 s
  • Measurement type: Systolic, Diastolic, Mean Measurement range (mmHg)

+ Range of Systolic pressure: Adult 40-270, Pediatric 40-200, Neonatal 40-135

+ Range of Diastolic pressure: Adult 10-210, Pediatric 10-150, Neonatal 10-95

+ Range of Mean pressure: Adult 20-230, Pediatric 20-165, Neonatal 20-105

  • Measurement accuracy
    + Maximum average error: ±5 mmHg
    + Maximum standard deviation: 8 mmHg
    + Resolution: 1 mmHg
  • Interval: 1, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minutes
  • Overpressure protection: Software and hardware, double safety protection

SpO2

  • Measurement range: 0-100%
  • Resolution: 1%
  • Accuracy: ±2% (70-100%, Adult/Pediatric); ±3% (70-100%, Neonate); 0-69%, unspecified
  • 0-69%, unspecified

Optional

  • Recorder
  • Masimo SET® SpO2