CRITICAL CARE PATIENT MONITOR CETUS x15
Model: CETUS x15
Manufacturer: Axcent Medical
Origin: Germany
Specifications:
Features:
- Patient: Adult, pediatric, neonatal
- 6” High resolution TFT LCD Touch screen
- 10 waveform display, up to 12-lead ECG analysis
- Pacemaker detection
- ST & arrhythmia analysis
- Wired/Wireless CMS, support HL7 protocol to HIS
- VGA support external display
- Graphical & tabular trend review (120 hours)
- 48 hours full disclosure wave review for each patient
Display
- 6” TFT (touch screen optional)
- Resolution: 1366 x 768
- Number of traces: 10 waveforms
I/O
- LAN: 1 standard RJ45 port
- WLAN: IEEE 802.11b/g/n
- USB: 2 USB connectors
- VGA: 1 VGA monitor connector (option)
- Output: 1 connector for Nurse call, Defib Sync Analog Output (options)
ECG
- Lead type: 3-lead, 5-lead,12-lead
- ECG waveform: 2 channels, 7 channels, 12 channels
- Display sensitivity: 2.5 mm/mV (×0.25), 5 mm/mV (×0.5), 10 mm/mV (×1.0), 20 mm/mV (×2.0)
- Wave sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- Differential input impedance >5MΩ
- Electrode polarization voltage range: ±400mV
- Baseline recovery time <3s after defibrillation (in monitor and surgery mode)
- Calibration signal: 1 mV (peak – peak), accuracy ±3%
RESP
- Measurement method: Thoracic electrical bioimpedance
- Rate: 0 – 150 bpm
- Measuring lead: Lead I, II
- Wave gain: ×0.25, ×0.5, ×1, ×2
- Respiratory impedance range: 0.5-5 Ω
- Baseline impedance: 500-4000 Ω
- Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
Pulse Rate
- Range: 30~254 bpm
- Resolution: 1 bpm
- Accuracy: ±2bpm (non-motion), ±5bpm (motion)
- Refreshing rate: 1s
TEMP
- Accuracy: ±0.1 or ±0.2 °F (without probe)
- Measurement range: 5~50℃ (41~122 °F)
- Channel: Two channels
- Resolution: 0.1℃
NIBP
- Measurement method: Automatic oscillometric method
- Operating mode: Manual, automatic, continuous
- Measurement unit: mmHg/kPa selectable
- Typical measurement time: 20~40 s
- Measurement type: Systolic, Diastolic, Mean Measurement range (mmHg)
+ Range of Systolic pressure: Adult 40-270, Pediatric 40-200, Neonatal 40-135
+ Range of Diastolic pressure: Adult 10-210, Pediatric 10-150, Neonatal 10-95
+ Range of Mean pressure : Adult 20-230, Pediatric 20-165, Neonatal 20-105
- Measurement accuracy:
+ Maximum average error: ±5 mmHg
+ Maximum standard deviation: 8 mmHg
+ Resolution: 1 mmHg
- Interval: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minutes
- Overpressure protection: Software and hardware, double safety protection
SpO2
- Measurement range: 0-100%
- Resolution: 1%
- Accuracy: ±2% (70-100%, Adult/Pediatric); ±3% (70-100%, Neonate); 0-69%, unspecified
- Refreshing Rate: 1s
Optional
- Masimo SET® SpO2
- IBP
- O
- Standard Mainstream CO2
- Standard Sidestream CO2
- Phasein ISA Sidestream CO2
- Phasein IRMA™ Mainstream CO2
- Phasein IRMA™ AX+ Mainstream Multi-gas
- Aspect BISx module
- NMT Tof-Watch® SX
- Recorder